Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master

Product Details
Customization: Available
Type: Cable and Antenna Analyzer
Wiring Devices: Site Master
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (19)
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
  • Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
WF-CAA-100B
Condition
New
Product Name
Cable and Antenna Cable Tester
Frequency Range
1MHz-6000MHz
Frequency Resolution
1kHz
Frequency Accuracy
2.5ppm
Transport Package
Standard Packing
Specification
37*23*27cm
Trademark
Onefind
Origin
China

Product Description

7 inch touch screen frequency up to 6GHz higher than Anritsu S331L WF-CAA-100B Site Master 

 

WF-CAA-100 Cable and Antenna Analyzer is desinged for the wireless service application of instalation and maintenance. It can measure Return Loss, VSWR, Cable Loss, DTF Return Loss, DTF VSWR and deliver easy and quick result presentation.

 

Measurements:

  • DTF Return Loss / VSWR, Frequency Return Loss /
  • VSWR and Cable Loss
  • Preset frequency bands / cable types or manual configuration
  • On-site cable calibration (propagation constant, cable loss etc.)
  • Convenient analysis tools: Marker, Limit, Scale, Smooth/Average
  • Up to 1103 data points
  • Professional test analysis and management software
  • CSV file format and JPEG screenshot
  • 2GB memory space
  • 7" color touch screen
  • 8 hours+ continuous operating time
  • Compact and robust
Specification:
 
Model WF-CAA-100B
Frequency Range 1Mhz-6000MHz
Frequency Resolution 1kHz
Frequency Accuracy ±2.5ppm
Output Power 0dBm(typ.)
Measurement Speed 3.5ms/point
Data Points 137, 251, 551, 1103
Anti-jamming Capability
Frequency -5dBm
Channel +17dBm
Directivity 42dB (after calibration)
Return Loss
Return Loss Range 0 - 60 dB
Return Loss Resolution 0.01dB
VSWR
VSWR Range 1 - 65
VSWR Resolution 0.01
Cable Loss
Cable Loss Range 0 - 30dB
Cable Loss Resolution 0.01dB
Distance-to-Fault
Distance-to-Fault Return loss Range 0 - 60 dB
Distance-to-Fault SWR Range 1 - 65
Measuring Length 1500m
Resolution Ratio ( 1.5×108 ) × (Vp) / (F2-F1)
Where Vp is the cable's relative propagation velocity.
where F2 is the stop frequency and F1 is start frequency
Data Points 1.37E+12
General Information
Connector Type N-Type female
Input Impedance 50 Ohm
Display 7 inch resistor touch screen, resolution 800×480
Data Interface One USB Host Port
One USB Device Port
One 10M/100M Adaptive LAN Port
Memory Space >2000 traces
Internal Battery 11.1V 7800mAh Rechargeable Lithium Battery
External Adapter 110 - 240V, 50 - 60Hz, AC input; 16V, 3.75A, DC output
Operating Temp. Range 10 - +50 °C
Storage Temp. Range 40 - +70
Humidity 0 - 85% (Non-Condensing)
Weight 2.5kg (Suttle)
Dimensions (L x W x H) 290×175×75mm
TPM Module (Optional)--RF Terminal Power Meter
Frequency Range 50 - 4000MHz
Power Range -40 - 20 dBm
Maximum Power <23 dBm
Measure Uncertainty ≤ +/-0.3dB (15 - 35)
≤ +/-0.5dB( 0 - 50)
Input VSWR <1.2
Burst Width 1µs - 60ms
Min Repetition Period 15Hz
Video Band 5MHz
Minimum Pulse Width 200ns
Time Resolution 0.1µs,1µs,15µs,150µs
Peak Average Ratio <12dB
CCDF Range 0.1% - 100%
CCDF Uncertainty ±3%
Duty cycle 0.1% - 100%
Power Supply USB
Operating Temp. Range 0 - 50
Storage Temp. Range -20 - 70
Humidity 0 - 85% (Non-Condensing)
Weight 0.3kg
Dimensions (L x W x H) 105(125)×45×35mm
Anti-vibration properties Conform to MIL-PRF-28800F class 3
Elect. Compatibility Characteristics Conform to EMC GB/T 18268-2000
SPM Module(Optional)--In Line Digital Frequency Spectrum Power Meter
Frequency Range 400MHz - 4000MHz
Return Loss 0 - 23dB
Max. Power 57dBm
Input VSWR <1.1
Insertion Loss ≤0.1dB
Directivity ≥30 dB(<3GHz); ≥28 dB(>3GHz)
Operating Mode Full Span/Arbitrary Span/Zero Span
Frequency Scanning Parameters(Full Span, Any Non-zero Span)
Filter Bandwidth 20M/300K optional
Scan Data Points Max. 551 points
Frequency Measurement Resolution 100KHz
Power Range 10dBm - 57dBm
Power Measurement(Zero Span)Parameters
Power Range Average: 100mW - 200W or 20 - 53dBm
Peak: 100mW - 500W or 20 - 57dBm
Peak-to-Average Ratio <12dB
CCDF 0.1 - 100%
Power Resolution ±0.01 dBm
Power Accuracy(Zero Span) ±0.5dB
Burst Signal Measurement Parameters
Burst Width 30µs - 100ms
Sampling Rate 300K/30K/5K optional
Duty Cycle 0.001 - 1
Burst Average Power 100mW - 200W or 20 - 53dBm
Others
PC Interface USB/RS-232
RF Interface N - Type female
Power Supply USB Power supply: 5V, 500mA
Power Consumption ≤ 2W
Operating Temp. Range -20 - 50
Storage Temp. Range -20 - 70
Humidity 0 - 95%(Non-Condensing)
Weight 490g
Dimensions (L x W x H) 130 (95)×124×34mm
Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master
 

 

FAQ

Wf-Caa-100b 7 Inch Touch Screen Frequency up to 6GHz Higher Than Anritsu S331L Site Master  

 

1.  Beijing W&F technology Co.,LTD is founded in 2006.We locate in Beijing- the capital of China. More than 15 years professional experience in fiber optic euqipments field makes us pay more attention to the quality.

2. Our brand ONEFIND are selling all over the world.

3. Life long technical support, quick feedback to any problem.

4. We can also provide OEM service.

5. "Satisfaction of the clients is service standard" --is our marketing service strate.

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier