Customization: | Available |
---|---|
Type: | Vector Network Analyzer |
Wiring Devices: | Vector Network Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
W&F 3656A/BA/D Radio communication Vector Network Analyzer
100kHz ~ 20 GHz
3656A/BA/B/D vector network analyzer is applicable to fields of radio communications, cable TV, teaching and automotive electronics etc. It can be used for performance measurement of RF components such as filter, amplifier, antenna, cable, and cable television sub connectors etc. It adopts Windows operating system, and has functions of error calibration, time domain and fixture simulator; It supports multiple display formats such as logarithmic amplitude, linear amplitude, standing wave, phase, group delay, Smith chart and polar coordinates etc.; It provides multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port, rapid SOLT calibration and electrical calibration; It is capable of multi-channel and multi-window display; It is designed with USB interface, LAN interface, GPIB interface and VGA interface. It can rapidly and accurately measure the amplitude, phase and group delay characteristics of the DUT S-parameter, with efficient and powerful error correction capability.
3656A/BA/B Technical Specifications
Parameters |
3656A |
3656BA/B |
Frequency range |
100kHz ~ 3GHz |
100kHz ~ 6.8GHz /8.5GHz |
Frequency resolution |
1Hz |
1Hz |
Frequency accuracy |
±5×10-6(23±3) |
±5×10-6(23±3) |
Output power setting range |
-45dBm~+10dBm |
-55dBm~+10dBm |
System dynamic range
|
(10Hz) (3kHz) 100kHz~1MHz 90dB 60dB 1MHz~10MHz 110 dB 80 dB 10MHz~3GHz 125dB 95dB |
(10Hz) (3kHz) 100kHz~20MHz 110dB 80dB 20MHz~3GHz 125 dB 95 dB 3GHz~6GHz 123dB 93dB 6GHz~8.5GHz 118dB 88dB |
Reflection track |
100kHz~10MHz ±0.030dB 10MHz~3GHz ±0.020dB |
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Transmission track |
100kHz~10MHz ±0.030dB 10MHz~3GHz ±0.020dB |
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Effective directivity |
100kHz~10MHz 49 dB 10MHz~3GHz 46 dB 100kHz~10MHz 49dB (option H01) 10MHz~3GHz 46dB (option H01) |
100kHz~3GHz 46dB 3GHz~6GHz 40dB 6GHz~8.5GHz 38dB |
Effective source match |
100kHz~10MHz 44dB 10MHz~3GHz 40dB 100kHz~10MHz 43dB (option H01) 10MHz~3GHz 21dB (option H01) |
100kHz~3GHz 36dB 3GHz~6GHz 35dB 6GHz~8.5GHz 33dB
|
Effective load match |
100kHz~10MHz 49 dB 10MHz~3GHz 46 dB 100kHz~10MHz 48dB (option H01) 10MHz~3GHz 41dB (option H01) |
100kHz~3GHz 44dB 3GHz~6GHz 40dB 6GHz~8.5GHz 36dB
|
Test points |
1 to 16001 |
|
IF bandwidth |
Min. 1Hz;Max. 5MHz,in 1,2,3,5,7 step |
|
Port connector type |
Type-N (female) 50 ohm system impedance Type-N (female) 75 ohm system impedance(3656-H01) |
|
Number of test ports |
2 |
|
Number of test receivers |
4 |
|
Reference level amplitude setting |
Setting range: ±500dB Setting resolution: 0.001dB |
|
Reference phase setting |
Setting range: ±500° Setting resolution: 0.01° |
|
Time-base reference output |
Output frequency: 10MHz Output level: +10dBm±4dB |
|
Digital interface |
GPIB, USB, Ethernet interface and VGA display interface |
|
Operation system |
Windows XP |
|
Display |
10.4-inch high brightness LCD |
|
Test domain |
Frequency domain, Time domain |
|
Dimensions |
435×233×348 (W×H×D) (including foot pad, foot, lateral stripping, input and output port) |
|
Power consumption |
150W |
|
Power supply |
50Hz single phase 220V or 50Hz/60Hz single phase 110V AC |
|
Weight |
16kg |
3656D Technical Specifications:
Parameters |
3656D |
||
Frequency range |
300kHz ~ 20GHz |
||
Frequency resolution |
1Hz |
||
Frequency accuracy |
±1×10-6(23±3) |
||
System dynamic range IF bandwidth:10Hz |
Frequency range |
2-port |
4-port |
300kHz~100MHz |
95dB |
90 dB |
|
100MHz~1GHz |
110dB |
100 dB |
|
1GHz~6GHz |
120dB |
115 dB |
|
6GHz~8GHz |
117dB |
110 dB |
|
8GHz~10GHz |
115dB |
105 dB |
|
10GHz~15GHz |
110dB |
100 dB |
|
15GHz~20GHz |
100dB |
90 dB |
|
Reflection track |
300kHz~10MHz ±0.030dB 10MHz~3GHz ±0.040dB 3GHz~20GHz ±0.050dB |
||
Transmission track |
300kHz~10MHz ±0.030dB 10MHz~3GHz ±0.040dB 3GHz~6GHz ±0.100dB 6GHz~20GHz ±0.150dB |
||
Effective directivity |
300kHz~10MHz 46dB 10MHz~3GHz 42dB 3GHz~6GHz 38dB 6GHz~20GHz 36dB |
||
Effective source match |
300kHz~10MHz 37dB 10MHz~3GHz 37dB 3GHz~6GHz 31dB 6GHz~20GHz 28dB |
||
Effective load match |
300kHz~10MHz 44dB 10MHz~3GHz 42dB 3GHz~6GHz 38dB 6GHz~20GHz 36dB |
||
Test points |
1 to 16001 |
||
IF bandwidth |
Min. 1Hz;Max. 5MHz,in 1,2,3,5,7 step |
||
Port connector type |
3.5mm (male) 50 ohm system impedance |
||
Number of test ports |
2/4 |
||
Number of test receivers |
2/4 |
||
Reference level amplitude setting |
Setting range:±500dB Setting resolution:0.001dB |
||
Reference phase setting |
Setting range:±500° Setting resolution:0.01° |
||
Time-base reference output |
Output frequency:10MHz Output level:+10dBm±4dB |
||
Digital interface |
GPIB, USB, Ethernet interface and VGA display interface |
||
Operation system |
Windows XP |
||
Display |
10.4-inch high brightness LCD |
||
Test domain |
Frequency domain, Time domain |
||
Dimensions |
436×236.5×410 (W×H×D) (including foot pad, foot, lateral stripping, input and output port) |
||
Power consumption |
150W |
||
Power supply |
50Hz single phase 220V or 50Hz/60Hz single phase 110V AC |
||
Weight |
18kg |